VHS-400

VHS-400

Category: Diffusions Pumps

Specifications
Details

Available in 4-inch, 6-inch, 250-mm, 10-inch, and 400-mm sizes, the VHS series pumps are the fastest and cleanest diffusion pumps of their size available today. The VHS series patented Bulge Contour doubles gas capture and maintains lower pressure. All VHS series pumps have sight glass/fill and drain assemblies for continuous monitoring and easy maintenance of pump fluid. Finned boilers increase surface area, prolonging pumping fluid life. Full thermal protection and quick-cool coils are also standard. The 4-inch, 6-inch, and 10-inch pumps can be ordered with ASA or ISO flanges, standard or extended cold caps, and a variety of voltages.

  • Highest pumping speed available for its height.
  • Fluid-level sight glass provides quick indication of pump fluid status at all times.
  • Fill and drain assembly for pump oil.
  • High throughput, 5100-watt version available.
  • Four-stage fractionating jet purifies pumping fluid.
  • High tolerable forepressure.
  • Full thermal protection.
  • Finned boiler increases surface area, prolonging pumping fluid life.
  • Quick cool coil is standard.
  • Foreline baffle prevents fluid loss into backing system

Technical Specifications

Pumping Speed, Operating Range Pumping Speed, AVS 4.1 (1963) 4,500 l/s Air, 5,625 l/s He/H2 8,000 l/s Air
Maximum Throughput 6.3 T-l/s (8.4 mbar l/s) in operating range 7.5 T-l/s (10.0 mbar l/s) @ 0.01 torr
Operating Range 1.4 x 10-3 to <5 x 10-9 torr (1.9 x 10-3 to <6.5 x 10-9 mbar)
Maximum Forepressure No Load: 0.65 torr (0.85 mbar) Full Load: 0.55 torr (0.72 mbar)
Recommended Backing Pump ≥30 cfm (51 m3/hr)
Backstreaming Rate, Standard Cold Cap <1.0 x 10-3 mg/cm2/min
Warmup Time 15 minutes
Cooldown Time 25 minutes
Fluid Charge 1,000 cc
Electrical Requirements 3 ph, 50/60 Hz, 208/380/480 VAC
Pump Power 4400 watts
Cooling Water Requirements 0.40 gpm (80 l/hr)
Water Connections
  • 1⁄8 in. FPT Tee

 

Speed Curve Graph

Pumping Speed Throughput

Outline DrawingVHS-400 Diffusion Pump Outline Drawing


Description Weight kg (lbs) Part Number
VHS-400 Pump with standard cold cap
208 V with ASA flanges 75.0 (180.0) K4816307
208 V with ISO flanges 75.0 (180.0) L9767307
240 V with ASA flanges 75.0 (180.0) K4816308
240 V with ISO flanges 75.0 (180.0) L9767308
380 V with ASA flanges 75.0 (1800) K4816326
380 V with ISO flanges 75.0 (1800) L9767326
480 V with ASA flanges 75.0 (1800) K4816309
480 V with ISO flanges 75.0 (1800) L9767309
Accessories
DC-702 pump fluid, 500 cc (two required) 1.4 (3.0) 695472005
DC-704 pump fluid, 500 cc (two required) 1.4 (3.0) 695474005
DC-705 pump fluid, 500 cc (two required) 1.4 (3.0) 695475005
Centering ring for ISO inlet flange, 400K 0.5 (1.0) IC400SV
Centering ring for ISO foreline flange, 63K 0.5 (1.0) IC63SV
Instruction manual   699901023
Replacement Parts
Heater, 208 V 2200 W (two required per pump) 0.5 (1.0) 647310140
Heater, 208 V 2550 W (two required per pump) 0.5 (1.0) 647310145
Heater, 240 V 2200 W (two required per pump) 0.5 (1.0) 647310150
Heater, 240 V 2550 W (two required per pump) 0.5 (1.0) 647310155
Heater, 380 V 2200 W (two required per pump) 0.5 (1.0) 647310160
Heater, 380 V 2550 W (two required per pump) 0.5 (1.0) 647310165
Heater, 480 V 2200 W (two required per pump) 0.5 (1.0) 647310170
Heater, 480 V 2550 W (two required per pump) 0.5 (1.0) 647310175
Heater crush plate (one required per pump) 1.0 (2.0) K7667001
Heater clamping plate (one required per pump) 0.5 (1.0) K4928001
Replacement nickel heater wire 0.5 (1.0) 656179100
O-ring kit, 1 for inlet (butyl, 2-385), 1 for foreline (butyl, 2-338), 10 for fill and drain (Viton, 2-113) 0.5 (1.0) K0377189
Thermal switch (set at 300 °F/147 °C) 0.5 (1.0) 642906025


View more about VHS-400 on main site